ARITECH CD72 PDF

Thank you for choosing an ARITECH security system. This manual explains how to use the ARITECH CD72 and CD95 series for every day use. There is a. A dual com polls to the monitoring station. What this means is every couple of minutes (depending on what it is set up for) it sends a signal to the monitoring. Hello, I want to integrate a solution based on PLUGWISE and an Aritech Alarm Central. I could successful connect a printer SERIAL RS

Author: Mot Vunos
Country: Estonia
Language: English (Spanish)
Genre: Literature
Published (Last): 1 April 2016
Pages: 373
PDF File Size: 18.81 Mb
ePub File Size: 12.56 Mb
ISBN: 531-5-11203-983-9
Downloads: 81720
Price: Free* [*Free Regsitration Required]
Uploader: Molrajas

Aritech Advisor CD72 Installation Manual

Avoid loops of wire inside the control panel and route cables so they do not lay on top or underneath the printed circuit board. Overview of the dipswitches on remotes Dual loop connection of a detector with latch Overview of the dipswitches on Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel of niet mee geholpen bent!

De handleiding is 0,16 mb groot. One zone each is required for both tamper and the alarm. The arrows move the cursor during entry.

Can I get a GSM dailer in a aritech CD72 panel – Page 2 –

Supply only mains power to the control panel. Do not use a arjtech to power the system when installing or changing the installation.

Antwoorden worden ook per e-mail naar abonnees gestuurd. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email.

  CARTILLA DE SNELLEN AGUDEZA VISUAL PDF

You can also Private Message one of our Community Managers here.

Handleiding Aritech TD TD (pagina 6 van 32) (English)

Use of an extra power supply Auxiliary power supply PG 4-wire bus of keypad or expander Figure Close the tamper switches on the remote keypads, expanders and the control panel. Dual loop connection of a detector with latch Note: Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Connecting a fire detector This connection also applied for detectors which require a reset after an alarm, e. Remote 1 must be a keypad. Ensure that there is a good earth for the alarm system.

Stel uw vraag in het forum. Got it, continue to print. Set the DIP switches of all the remote keypads and expanders.

This fixing screw is used for pry-off tamper. Intended for the manager.

The dialler may also be programmed via the keypad. The zone is Resistance Panel zone voltages Remote zone voltages Reaction on standby 3k5 – 6k2 2. Figure 2 shows how they are connected.

Get out there and share your passion with others!

If this is not possible, shielded cable should be used and the cable should be earthed at the control panel end ONLY. Remote 1 must be a keypad. Numbering of the inputs Note: If a short circuit should occur, remove the 12 volt connections one by one. Keys on a CD30xx Do not use a battery to power the system when installing or changing the installation. By continuing to browse this site you are agreeing to our use of cookies.

  BAHUTU MANIFESTO PDF

Page 6 Connecting a fire detector One zone each is required for both tamper and the alarm.

Screw to close siren. If the sirens have been activated, these will now stop. Overview of the inputs and outputs on the CD Output no. When used in conjunction with the Programming Manual and the User Manual, it provides the installation engineer with basic installation and programming information.

Aritech TD8803 TD8412

Further SLC BV reserve the right to revise this publication and to make changes from time to time in the contents hereof without the obligation of SLC BV to notify any person of any such revision. Wij controleren de vraag en zonodig wordt deze verwijderd. If dual loop is programmed, the letter T will appear next to the zone number to indicate the tamper section of the loop is open.

Connection of a fire detector Detectors or key switches can be connected in two ways: Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider. Set the DIP switches of all the remote keypads and expanders. Everybody involved in installing or maintaining this panel should have access to a copy of this manual.