II ADNOC HEALTH, SAFETY AND ENVIRONMENT A Library of HSE Systems , Programs and Procedures will be maintained by. ADNOC E&S Division. HSE Manual Description. VIKING Emergency Training Drills. VIKING Planned Equipment and Facilities Controls. ADNOC 10 Golden Rules of Safety (GOLDEN RULES OF work activities in line with requirements of respective HSE procedures & manuals.

Author: Mushura Mozahn
Country: Kazakhstan
Language: English (Spanish)
Genre: Education
Published (Last): 19 September 2009
Pages: 306
PDF File Size: 16.90 Mb
ePub File Size: 17.70 Mb
ISBN: 650-7-20962-706-7
Downloads: 64817
Price: Free* [*Free Regsitration Required]
Uploader: Mezizilkree

This analysis must be repeated immediately before use of the gas. Canadian Category 3 Diver.

ADNOC 10 Golden Rules of Safety Pages 1 – 21 – Text Version | FlipHTML5

This level of training will also require refresher training at regular intervals normally every three years that will comply with DMAC Training [Ref. There are a number of hard bound logbooks available for this purpose, e. Dive A dive takes place when a person enters the water, a chamber, or any other environment in which he is subject to pressure greater than millibars above atmospheric pressure and who in order to survive in such an environment breathes in air or other gas at a pressure greater than atmospheric pressure.

This diver need not be dressed for diving provided the equipment is available, and may undertake other duties within kanual dive team while the bell is under water. A dive plan that includes the use of such units must therefore also manuzl safe operating procedures that are to be followed. The dive plan must include solutions for these hazards. Are diving related, or any other accidents and incidents, reported in an acceptable format and records kept?

  LUTRON EC3DT4MWKU1S PDF

Are minutes distributed to relevant offshore personnel, clients and sub-contractors?

This will confirm, as far as reasonably practicable, their fitness to enter saturation. This will prevent the diver being supplied with the wrong percentage of oxygen even if the breathing medium adnco compressed air.

jQuery UniSlider

This will normally mean establishing that the person has had sufficient training coupled with experience. As a guideline, repetitive diving should be restricted to exceptional circumstances e.

Obtain any necessary permission before starting or continuing the operation, normally via a Permit To Work PTW system. The Diving Supervisor must also locate the nearest chamber and have an agreement that in an emergency yse, facilities will be available. Any such handovers of responsibility must be recorded in writing in the diving operations log.

ADNOC 10 Golden Rules of Safety

The dive plan must ensure that in a nanual bell, neither diver spends more than 6 hours out of the bell. Diving Contractors must prepare and authorize the use of such checklists as part of the planning for projects.

Does the Contractor distribute the Diving Safety documentation to sites and appropriate client and sub-contractor positions.? To allow for these breaks, the Diving Contractor must ensure that the planned work either has natural breaks for example, during periods of strong tide or that qualified and experienced personnel are available to act as relievers during breaks.

Allowances must also be made for leakage, wastage, and contingencies.

Such checks must be documented, for example, on a pre- prepared checklist, and recorded in the diving operations log for the project. For such diving a properly equipped wet bell must be used and the maximum depth must be limited to 75 m of water for 30 minutes. Diving rules Diving ManualEmergency Procedures and work procedures must also be submitted to the relevant department for review and mahual.

  GEOMETRIE DIFFERENTIELLE COURS PDF

Such a system may be based on passage of time, amount of use, manufacturer recommendations or previous operational experience, but ideally will be based on a combination of all of these. These schools are independently audited and certificates from them can be adnlc as showing suitable basic training. The design must also prevent spinning or tipping, protect the divers from falling objects and carry sufficient breathing media for emergency purposes [Ref.

If there are any intakes or discharges, suitable arnoc must be taken to ensure that these cannot operate while divers are in the water unless the divers are protected with a suitable physical guard. In particular, the adhesive used in these discs tends to degrade in water. Norwegian NPD surface diver. Conversely, in very warm waters nothing more than cotton overalls may be reguired.

Full text of “ADNOC COPV 4 09( Ver 1)”

Purpose The purpose of this exercise is to ensure that the initial safety assessment of a Contractor is conducted in a consistent and auditable manner. Company Medical Adviser A nominated diving medical specialist appointed by a Diving Contractor to provide specialist advice. The hsee shall be carried out by authorised and certified person only.